ACR-News

 

Daimler shuns new refrigerant R1234yf

GERMANY: Daimler, the manufacturer of Mercedes-Benz cars, has said it will not be using the new HFO refrigerant R1234yf in its vehicle air conditioning systems. Instead, it says it wishes to continue using R134a.
Following its own independent safety tests, the German car and truck manufacturer has raised safety concerns with usage of the new internationally recognised refrigerant replacement for R134a.

While concerns had been raised previously - particularly in Germany - as to its 'mild' flammability, the climate-friendly R1234yf was set to be used worldwide in the automotive industry and was previously perceived to be safe. This was determined by numerous laboratory and crash tests carried out by international vehicle manufacturers and independent institutions.

Daimler says it has carried out a series of additional tests on the new refrigerant as part of a new real-life test scenario developed in-house which goes above and beyond the legally prescribed requirements.

'In the new real-life test scenario, the refrigerant is dynamically dispersed at high pressure near to hot components of the test vehicle's exhaust system,' says the report. 'This corresponds to a serious head-on collision in which the refrigerant line is severed and the reproducible results demonstrate that refrigerant which is otherwise difficult to ignite under laboratory conditions can indeed prove to be flammable in a hot engine compartment.'

Daimler says that similar tests carried out with the current R134a refrigerant did not result in ignition.

'Due to the new findings of this study and the high safety demands at Mercedes-Benz, this chemical will not be used in its products,' says a company statement. 'The company therefore wishes to continue to use the proven and safe R134a refrigerant in its vehicles. Daimler has already informed the relevant authorities of these facts and will also make the results of this investigation available to all relevant associations as well as to other vehicle manufacturers,' it says.

The IOR Annual Conference – a conference on-demand

Delegates to the IOR Annual Conference taking place from 21 to 22 April will get the chance to access the event live and all sessions and recordings for up six months afterwards providing fantastic value and allowing anyone registering for the event ...

  01-Apr-2021

Thunder: the full inverter reversible R290 heat pump from 40 to 85 kW

Thunder is the newest solution from Clivet, designed with full-inverter technology on latest-generation scroll compressors and axial fans....

  24-Apr-2024

Customised Consulting TM44 Inspection Services

Customised Consulting are accredited to provide TM44 Inspection Services ((also known as Air Conditioning Energy Assessments (ACEA)) for both simple (level 3) and complex (level 4) systems for buildings and can provide competitive quotes in Weybridge, Surrey, Sussex, London and Kent.
  25-Apr-2024
https://www.acr-news.com/daimler-shuns-new-refrigerant-r1234yf