Q-ton delivers low carbon hot water for Citadines hotel

A London hotel has recently upgraded its hot water generation plant using the Q-ton air-to-water heat pump system from Mitsubishi Heavy Industries (MHI).

The Citadines Holborn-Covent Garden London originally had gas-fired boilers, which provided potable hot water to the apart’hotel’s 192 apartments and communal breakfast area. Citadines required a replacement that could provide water at high temperatures, whilst ensuring minimal environmental impact.

The project at Citadines Holborn-Covent Garden, part of The Ascott Limited portfolio - CapitaLand’s wholly owned lodging business unit – is part of CapitaLand’s 2030 Sustainability Master Plan targets.

As part of the Master Plan, a phased installation will also see the Q-ton system deployed at four other Citadines sites across the capital, in Islington, Barbican, South Kensington and Trafalgar Square.

Ideal product

Ryan Jules, regional maintenance manager at The Ascott Limited UK, who hired KiPO Consultancy to assist with the key sustainability carbon reduction project, said: “This a significant investment and action towards meeting both the UK Government and CapitaLand’s 2030 Sustainability Master Plan target of a 78 per cent reduction in carbon emissions by 2035, for the UK Government, and 2030 for CapitaLand.”  

Martin Craxton, of consulting engineers KiPO, worked closely with Citadines to develop a complete renewable solution for the hotel chain. He said: 'Q-ton is an ideal product for commercial water heating applications. It uses CO2, a natural refrigerant with ultra-low global warming potential, to produce hot water ranging from 60-90°C. Q-ton holds efficiencies when operating right up to 70°C, which is required by the hotel to combat legionella growth.

“Whilst the Q-ton solution was marginally more expensive on capital costs than the traditional gas-fired as alternative, the client was willing to make this extra investment, demonstrating their commitment to sustainability. Central London’s atmosphere is now rid of the hotel’s 600 kW of gas-burning emissions. Q-ton holds its capacity down to -7°C ambient and still provides full operation at -25°C.”

Unlike water heaters using gas or oil, renewable heating systems are not usually designed for instant hot water. Instead, KiPO designed the system using a method known as energy accumulation to meet the apart’hotel's usage profile and peak load. The heat pump generates the energy, and a thermal store holds the hot water until it is used.

Principal contractor Nationwide Air Conditioning installed three Q-ton heat pump units and six 1000-litre storage vessels at ground level while the original gas-fired water heaters at the roof level were still in use. The transition to the new system took just a few hours towards the end of the project, ensuring minimum disruption to the property. Nationwide Air Conditioning was supported throughout the installation by the MHI specifications team. This included online design, training, system design schematics, a pre-commissioning site visit and assistance with final commissioning.

Daniel Valente, project manager at Nationwide Air Conditioning, said: 'The support provided by the MHI specifications team throughout the design and installation period made the project very straightforward. As a modular system, Q-ton is simple to install and commission, with minimal wiring and straightforward controller setup. On commissioning it was evident that the Q-ton equipment was more than capable of producing hot water at 70°C, and the 6000 litres of storage ensured that the system could cope with periods of peak hot water demand.

“We look forward to installing and maintaining many more Q-ton systems in the future and can see them becoming a crucial tool in collectively reducing CO2 emissions across many industries that generate large quantities of domestic hot water.' 

Perfect operation

In addition, the building is equipped with a Q-ton Remote Monitoring System (QRMS), a tool that monitors Q-ton’s operation, provides the team with a quarterly report comparing energy usage and efficiencies against gas and electric equivalents and self-analyses to highlight any potential operation or maintenance requirements.

Germana Genovese, residence manager at Citadines Holborn-Covent Garden, said: 'We are delighted to be using heat pump technology as a primary method for our hot water generation. The Q-ton's operation has been perfect, and we're looking forward to seeing how efficiently the system works during its first winter compared to the gas boilers we previously had. Everyone needs to do their bit to help achieve the government targets of net zero and we are proud to play our part.'

Comments

Already Registered?
Sign In
Not Yet Registered?
Register

The IOR Annual Conference – a conference on-demand

Delegates to the IOR Annual Conference taking place from 21 to 22 April will get the chance to access the event live and all sessions and recordings for up six months afterwards providing fantastic value and allowing anyone registering for the event ...

  01-Apr-2021

Enter the Clivet Assen Superbikes Competition!

Win hotels, flights, and VIP Tickets for two to watch Mikey Hardie #93 up close and personal and have the VIP Experience at British Superbikes in Assen, Netherlands....

  22-Apr-2025

Sanhua’s REVOlution for supermarket refrigeration

SANHUA is proud to present its latest innovation in refrigeration technology – the REVO series of controllers. Designed to provide a wide range of applications, the REVO controllers offer high performance and efficiency, ensuring that your refrigerated cabinets maintain optimal conditions for fresh food preservation.
  02-Apr-2025
ACR News is the number one magazine in the air conditioning and refrigeration industry. Don’t miss out, subscribe today!
Subcribe to ACR News

Diary

UK Construction Week
BESA Annual Conference & Awards